Advantages
- Significant radiant heat insulation.
- Wind, vapour and water barrier.
- High durability, high tear resistance, light weight, and user friendly
Applications Fields
- Loft
- Metal roofs
- Conductive roof and wall contsruction
- Technical Data
PROPERTIES | METHOD | UNIT | VALUES |
MIN. TOLERANCES |
MAX. TOLERANCES |
Lenght | TS EN 1842-2 | m | 50 | 0% | 4% |
Width | TS EN 1842-2 | mm | 1500 | -0.50% | 1.50% |
Mass per Unit Area | EN 1849-2 | gr/m² | 130 | -10 | 10 |
Reaction to Fire Class | EN 13501 / EN 11925-2 | Class | E | - | - |
Resistance to Water Penetration | EN 1928 Method A | Class | W1 | - | - |
Water Vapor Transmission Properties (Sd) | EN 1931 | m | >180 | -0.015 | 0.01 |
Tensile Properties: Maximum Tensile Force | EN 12311-1 / EN 13859-1B | N / 50mm | MD 779 / CD 389 | MD-40 / CD-30 | MD 55 / CD 45 |
Elongation | EN 12311-2 / EN 13859-1B | % | MD 32 / CD 10 | MD-10 / CD-15 | MD 15 / CD 20 |
Resistance to Tearing | EN 12310-1 / EN 13859-1A | N | MD 127 / CD 164 | MD-40 / CD-50 | MD 75 / CD 75 |
Joint Strength | EN 12317-2 | N | MD 344 / CD 230 | MD-40 / CD-50 | MD 75 / CD 75 |